Regular Hip/Valley and Jack Rafters
A roof’s Pitch is 255/300 mm and half the
total span is 1800 mm. Find the lengths of
the Common, Hip/Valley and Jack rafters.
Also find the incremental jack adjustment
and the cut angles. (Jack rafters at 400
mm On-center spacing.)
KEYSTROKE DISPLAY
1. Find the Common rafter length:
o o 0.
1 8 0 0 Ç 9 R RUN 1800. MM
2 2 5 Ç 9 p PTCH 225. MM
d (Common) DIAG 2237. MM
2. Find the Hip/Valley rafter length and cut
angles; then the incremental jack adjust-
ment, Jack rafter lengths and cut angles:
H H/V 2872.
MM
H PLMB 27.56°
H LEVL 62.44°
H CHK1 45.00°
j JKOC
STORED
400. MM
j INCR 497. MM
j JK 1 1740. MM
j JK 2 1243. MM
j JK 3 746. MM